Check valve slam analysis in pumping station
dc.contributor.author | Himr, Daniel | cs |
dc.contributor.author | Habán, Vladimír | cs |
dc.contributor.author | Dokoupil, Pavel | cs |
dc.coverage.issue | 2016 | cs |
dc.coverage.volume | 114 | cs |
dc.date.issued | 2016-03-28 | cs |
dc.description.abstract | Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system. | en |
dc.description.abstract | Čerpací stanice dodává vodu pro technologický proces. Zpětný ventil na stanici byl nahrazen novým. Pravidelná zkouška výpadku objevila pulsace vysokého tlaku spolu s znatelným pohybem výtlačného potrubí. To bylo způsobeno pozdním zavřením zpětné klapky, pravděpodobně, když zpětný tok dosáhl nejvyšší možné rychlosti. Toto tvrzení bylo podpořeno analýzou výsledků měření tlaku poblíž zpětného ventilu a numerická simulace proudění v potrubním systému. | cs |
dc.format | text | cs |
dc.format.extent | 1-6 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | EPJ Web of Conferences. 2016, vol. 114, issue 2016, p. 1-6. | en |
dc.identifier.doi | 10.1051/epjconf/201611402038 | cs |
dc.identifier.issn | 2100-014X | cs |
dc.identifier.orcid | 0000-0003-4500-8631 | cs |
dc.identifier.orcid | 0000-0002-5445-3537 | cs |
dc.identifier.other | 123443 | cs |
dc.identifier.scopus | 55823004900 | cs |
dc.identifier.scopus | 15729076600 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/84112 | |
dc.language.iso | en | cs |
dc.publisher | EDP Sciences | cs |
dc.relation.ispartof | EPJ Web of Conferences | cs |
dc.relation.uri | http://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02038/epjconf_efm2016_02038.html | cs |
dc.rights | Creative Commons Attribution 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/2100-014X/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.subject | water hammer | en |
dc.subject | check valve | en |
dc.subject | vodní ráz | |
dc.subject | zpětný ventil | |
dc.title | Check valve slam analysis in pumping station | en |
dc.title.alternative | Analýza práskání zpětného ventilu v čerpací stanici | cs |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-123443 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 15:47:08 | en |
sync.item.modts | 2025.01.17 15:33:35 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta strojního inženýrství. EÚ-odbor fluidního inženýrství Viktora Kaplana | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- epjconf_efm2016_02038.pdf
- Size:
- 1.9 MB
- Format:
- Adobe Portable Document Format
- Description: