Abstract

Degradation processes affecting structural materials, such as chloride ion ingress, concrete carbonation, and the subsequent corrosion of reinforcement, are limiting factors for the service life of reinforced concrete structures and/or structural elements. The objective of a structural condition assessment is to determine the current state and estimate the future performance of a structure with a maximum degree of accuracy and a minimum of effort. There is therefore a need for advanced methodologies and predictive deterioration models for the assessment of structures/structural elements over time. In the paper, the focus is on the widely accepted models for modeling of chloride ion ingress into concrete and concrete carbonation process incorporated in the fib Model Code 2010. Three levels of assessment of input parameters are presented, starting with simple quantification based on codes/literature recommendations and progressing to higher levels of assessment using design documentation and visual inspection data, additional on-site measurements, and/or laboratory tests.
Degradation processes affecting structural materials, such as chloride ion ingress, concrete carbonation, and the subsequent corrosion of reinforcement, are limiting factors for the service life of reinforced concrete structures and/or structural elements. The objective of a structural condition assessment is to determine the current state and estimate the future performance of a structure with a maximum degree of accuracy and a minimum of effort. There is therefore a need for advanced methodologies and predictive deterioration models for the assessment of structures/structural elements over time. In the paper, the focus is on the widely accepted models for modeling of chloride ion ingress into concrete and concrete carbonation process incorporated in the fib Model Code 2010. Three levels of assessment of input parameters are presented, starting with simple quantification based on codes/literature recommendations and progressing to higher levels of assessment using design documentation and visual inspection data, additional on-site measurements, and/or laboratory tests.

Description

Citation

Structural Concrete. 2020, vol. 21, issue 4, p. 1377-1384.
https://onlinelibrary.wiley.com/doi/abs/10.1002/suco.201900401

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO