Hight Speed Temperature Measurement
dc.contributor.author | Rapta, Patrik | cs |
dc.contributor.author | Hejčík, Jiří | cs |
dc.contributor.author | Jícha, Miroslav | cs |
dc.coverage.issue | 1 | cs |
dc.coverage.volume | 264 | cs |
dc.date.issued | 2022-07-11 | cs |
dc.description.abstract | In certain applications where temperature changes rapidly, e.g., compressor cylinder or explosion chamber, it is necessary to obtain temperature data with sample rate high enough to register the change, i.e., the temperature probe response time must be very low. Type E coaxial thermocouple with response time in the range of us can be an example of such temperature probe. This paper describes several approaches for high frequency temperature data obtaining using the coaxial thermocouples. Individual approaches are described together with their related issues. The possible method of data evaluation is discussed. | en |
dc.format | text | cs |
dc.format.extent | 40-43 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | EPJ Web of Conferences. 2022, vol. 264, issue 1, p. 40-43. | en |
dc.identifier.doi | 10.1051/epjconf/202226401006 | cs |
dc.identifier.issn | 2100-014X | cs |
dc.identifier.orcid | 0000-0002-7270-3982 | cs |
dc.identifier.orcid | 0000-0002-2812-1379 | cs |
dc.identifier.orcid | 0000-0002-1409-5165 | cs |
dc.identifier.other | 174903 | cs |
dc.identifier.researcherid | CVT-7747-2022 | cs |
dc.identifier.scopus | 6504446107 | cs |
dc.identifier.scopus | 6602494673 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/208172 | |
dc.language.iso | en | cs |
dc.publisher | EPJ Web of Conferences | cs |
dc.relation.ispartof | EPJ Web of Conferences | cs |
dc.relation.uri | https://www.epj-conferences.org/articles/epjconf/abs/2022/08/epjconf_efm2022_01006/epjconf_efm2022_01006.html | cs |
dc.rights | Creative Commons Attribution 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/2100-014X/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.subject | coaxial thermocouple | en |
dc.subject | sample rate | en |
dc.subject | voltage | en |
dc.subject | data acquisition system | en |
dc.title | Hight Speed Temperature Measurement | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-174903 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 15:47:15 | en |
sync.item.modts | 2025.01.17 18:36:46 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta strojního inženýrství. EÚ-odbor termomechaniky a techniky prostředí | cs |