Modification of electrothermal atomic absorption spectrometry for determination of arsenic in high salinity samples
dc.contributor.author | Smolíková, Vendula | cs |
dc.contributor.author | Pelcová, Pavlína | cs |
dc.contributor.author | Hedbávný, Josef | cs |
dc.contributor.author | Zlámalová, Lucie | cs |
dc.contributor.author | Ridošková, Andrea | cs |
dc.date.accessioned | 2019-06-20T06:10:44Z | |
dc.date.available | 2019-06-20T06:10:44Z | |
dc.date.issued | 2019-01-02 | cs |
dc.description.abstract | The electrothermal atomic absorption spectrometry (ET-AAS) method was optimized for determination of the arsenic content in high salinity samples. The combination of palladium (1 g/l) modifier, graphite furnace temperature program and graphite tube modified with tungsten carbide significantly reduced the matrix interference in the sample with NaCl concentration of 10 g/l. Optimized temperature program ensured the reduction of the background absorbance about 95–100%. The modification of graphite furnace surface by tungsten carbides ensured the shift of background absorbance prior to the absorbance of the analyte and considerable extension lifetime of graphite tubes. | en |
dc.format | text | cs |
dc.format.extent | 527-531 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | MendelNet 2018. 2019, p. 527-531. | en |
dc.identifier.isbn | 978-80-7509-597-8 | cs |
dc.identifier.other | 156245 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/178387 | |
dc.language.iso | en | cs |
dc.publisher | Mendel University in Brno | cs |
dc.relation.ispartof | MendelNet 2018 | cs |
dc.relation.uri | https://mendelnet.cz/artkey/mnt-201801-0112_Modification-of-electrothermal-atomic-absorption-spectrometry-for-determination-of-arsenic-in-high-salinity-sam.php?back=/magno/mnt/2018/mn1.php?secid=4 | cs |
dc.rights | (C) Mendel University in Brno | cs |
dc.rights.access | openAccess | cs |
dc.subject | arsenic | en |
dc.subject | palladium modifier | en |
dc.subject | tungsten carbide | en |
dc.subject | ET-AAS | en |
dc.subject | background correction | en |
dc.title | Modification of electrothermal atomic absorption spectrometry for determination of arsenic in high salinity samples | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-156245 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2020.04.01 11:01:29 | en |
sync.item.modts | 2020.04.01 06:08:01 | en |
thesis.grantor | Vysoké učení technické v Brně. Středoevropský technologický institut VUT. Chytré nanonástroje | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Modification of electrothermal atomic absorption spectrometry for determination of arsenic in high salinity samples.pdf
- Size:
- 664.26 KB
- Format:
- Adobe Portable Document Format
- Description:
- Modification of electrothermal atomic absorption spectrometry for determination of arsenic in high salinity samples.pdf