Abstract

Process intensification is one of the key branches of process engineering. High gravity equipment achieves intensification by substituting gravity with much higher centrifugal force. Rotating Packed Bed is the leading example of high gravity solutions, strongly facilitating gas-liquid mass transfer. However, cylindrical packings come with certain drawbacks, such as dry spots, that can be overcome with new solutions, such as baffle-based packing geometries. However, when baffles are arranged too close to each other, liquid bridges are formed between them, which may lead to decrease in mass transfer efficiency. This work is concerned with improvement of a Zickzack-like internal by the means of visual studies with the use of high-speed camera. According to measured ligament break-up length, two new packings were designed for particular rotational speeds and tested experimentally for effective mass transfer area and wet pressure drop.
Process intensification is one of the key branches of process engineering. High gravity equipment achieves intensification by substituting gravity with much higher centrifugal force. Rotating Packed Bed is the leading example of high gravity solutions, strongly facilitating gas-liquid mass transfer. However, cylindrical packings come with certain drawbacks, such as dry spots, that can be overcome with new solutions, such as baffle-based packing geometries. However, when baffles are arranged too close to each other, liquid bridges are formed between them, which may lead to decrease in mass transfer efficiency. This work is concerned with improvement of a Zickzack-like internal by the means of visual studies with the use of high-speed camera. According to measured ligament break-up length, two new packings were designed for particular rotational speeds and tested experimentally for effective mass transfer area and wet pressure drop.

Description

Citation

Chemical and Process Engineering-New Frontiers. 2023, vol. 44, issue 3, p. 1-6.
https://journals.pan.pl/dlibra/publication/146730/edition/128663/content

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO