Luminous Intensity Distribution Curve Effect on Luminaire Placement

Loading...
Thumbnail Image

Date

Authors

Bayer, Rudolf
Brejcha, Michal

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií

ORCID

Altmetrics

Abstract

The paper discusses a way to deploy a given number of point light sources in the interior to provide required illuminance levels and uniformity of the working plane by using a genetic algorithm. Furthermore a genetic algorithm has been used to generate a proper luminous intensity distribution curve of multiple luminaires to meet the given criteria for the reference plane of the model room for predefined luminaire positions.

Description

Citation

Proceedings of the 21st International Conference LIGHT SVĚTLO 2015. s. 267-271. ISBN 978-80-214-5244-2