Abstract

Two types of light pipes of comparable dimensions were tested. The evaluation of light guides was based on data of long-term measurements of daylight illuminance. A set of illuminance meters distributed on the reference plane under the light pipes were used. The illuminance measurements were processed using a data collecting system. The system collected data for one-year continual measurements. The measured data analysis shows differences in the tested light pipes daylighting which is relevant to their practical applications.
Two types of light pipes of comparable dimensions were tested. The evaluation of light guides was based on data of long-term measurements of daylight illuminance. A set of illuminance meters distributed on the reference plane under the light pipes were used. The illuminance measurements were processed using a data collecting system. The system collected data for one-year continual measurements. The measured data analysis shows differences in the tested light pipes daylighting which is relevant to their practical applications.

Description

Citation

Przeglad Elektrotechniczny. 2022, vol. 2022, issue 4, p. 58-61.
http://pe.org.pl/articles/2022/4/13.pdf

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Citace PRO