Generated heat by different targets irradiated by 660 MeV protons

Loading...
Thumbnail Image

Authors

Svoboda, Josef
Adam, Jindřich
Foral, Štěpán
Gustov, S.A.
Katovský, Karel
Kushvatov, J.
Král, Dušan
Solnyshkin, Alexander A.
Tichý, Pavel
Tyutyunnikov, S.

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

Council of Scientific & Industrial Research - National Institute of Science Communication and Information Resources

Abstract

Calorimetric experiments have been performed to analyze different thick targets of natU, C, Pb material, irradiated by 660 MeV protons at the Phasotron accelerator facility, Joint Institute for Nuclear Research (JINR) in Dubna, Russia. The method of online temperature measurement has been compared with MCNPX 2.7.0 simulation and selected with Ansys Transient Thermal Simulation to compare measured temperature with the simulated one. Thermocouples type T and E have been used as a temperature probe. Many different positions have been measured for each target. Temperature results are following very well the processes inside of the cylinders. Changes of heat deposition caused by drops of the proton beam intensity are displayed very well as a jagged line shown in almost every chart. Accurate temperature changing measurement is a very modest variation of how to observe inner macroscopic behavior online.
Calorimetric experiments have been performed to analyze different thick targets of natU, C, Pb material, irradiated by 660 MeV protons at the Phasotron accelerator facility, Joint Institute for Nuclear Research (JINR) in Dubna, Russia. The method of online temperature measurement has been compared with MCNPX 2.7.0 simulation and selected with Ansys Transient Thermal Simulation to compare measured temperature with the simulated one. Thermocouples type T and E have been used as a temperature probe. Many different positions have been measured for each target. Temperature results are following very well the processes inside of the cylinders. Changes of heat deposition caused by drops of the proton beam intensity are displayed very well as a jagged line shown in almost every chart. Accurate temperature changing measurement is a very modest variation of how to observe inner macroscopic behavior online.

Description

Citation

INDIAN JOURNAL OF PURE & APPLIED PHYSICS. 2020, vol. 58, issue 4, p. 246-254.
http://nopr.niscair.res.in/handle/123456789/54502

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

DOI

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution-NonCommercial-NoDerivatives 2.5 Generic
Citace PRO